Наукові публікації кафедри БДМБ

Permanent URI for this collectionhttps://dspace.kntu.kr.ua/handle/123456789/1353

Browse

Search Results

Now showing 1 - 4 of 4
  • Item
    Досвід розрахунково-екпериментального оцінювання енергетичних показників будівлі школи
    (НУВГП, 2020) Настоящий, В. А.; Пашинський, В. А.; Пашинський, М. В.; Джирма, С. О.; Nastoiashchyi., V.; Pashynskyi, V.; Pashynskyi, M.; Dzhyrma, S.
    Висвітлена методика і результати оцінювання показників енергетичної ефективності будівлі школи з урахуванням теплових характеристик огороджувальних конструкцій, отриманих за даними вимірювань у процесі натурних обстежень. Проаналізовано вплив термомодернізації на клас енергетичної ефективності будівлі. During the examination, numerous damages of the outer wall cladding, unfilled seams between the wall blocks and poorly executed junction of window and door frames to a wall were revealed, where heat transfer is highly increased due to air leakage from the inside of the building. The actual values of the heat transfer resistance of walls and translucent structures, experimentally established using a thermohygrometer, do not meet the requirements of current standards. Examination of the outer walls and window blocks using a thermal imager revealed thermal anomalies that significantly reduce the thermal insulation characteristics of enclosure structures. It is noted that the use of technical devices makes it easy to detect thermal anomalies and to estimate the characteristics of enclosure structures. Based on the research results, an energy passport of the building was developed. The design value of specific energy consumption is 55.7 kW×h/m3. Taking into account the maximum value of 35 kW×h/m3 for educational institutions, that are a subject of thermal modernization, the building was examined and classified as energy efficiency class F. Design proposals have been developed for thermal modernization of the building by using ventilated facade systems with rockwool insulation. After thermal modernization, the specific energy consumption are reduced to 34.7 kW×h/m2, and the energy efficiency is improving to class C.
  • Item
    Методика аналізу процесу теплопередачі у вузлах огороджувальних конструкцій будівель
    (ОДАБА, 2020) Джирма, С. О.; Пашинський, В. А.; Настоящий, В. А.; Пашинський, М. В.
    Розроблена методика визначення втрат тепла через вузли огороджувальних конструкцій довільної форми. Методика базується на аналізі температури внутрішньої поверхні огороджень і дозволяє визначати втрати тепла в зонах лінійних теплопровідних включень та відповідні лінійні коефіцієнти теплопередачі. Встановлені параметри чисельного розв'язку, які гарантують достатню точність результатів. Виконані приклади визначення втрат тепла та лінійних коефіцієнтів теплопередачі для характерних вузлів стін житлових і громадських будівель. Достовірність результатів підтверджена шляхом порівняння лінійних коефіцієнтів теплопередачі з відомими даними для типових вузлів. The energy needs of buildings should be determined taking into account heat losses through zones of increased thermal conductivity in the junctions of enclosure structures. For this, linear heat transfer coefficients are used, which are given in the Ukrainian standard for a number of typical junctions. Non-standard solutions of junctions of enclosure structures require the development of a simple method for determining heat loss, which can be used for the design of real buildings. The proposed method is based on the analysis of the process of heat transfer from internal air to the inner surface of the enclosure. To determine the amount of heat, it is necessary to select a junction with adjacent flat sections of the enclosure and by two-dimensional computer simulation to determine the temperature on the inner surface of the enclosure. The amount of heat transferred is determined by numerical integration of the temperature difference between the internal air and the inner surface of the enclosure, taking into account the heat transfer coefficient of this surface. By the multi-variant calculations, it was found that the width of the adjacent junctions to the flat wall sections should be about two thicknesses of the wall. For a sufficiently accurate determination of heat loss using the trapezoidal rule, the discretization step of the temperature of the inner surface should not exceed 40 ... 50 mm. The developed technique also allows to determine the linear heat transfer coefficient of the junction. It is equal to the difference between the total amount of heat transferred and the amount of heat that can be transmitted through the flat sections of the enclosure, divided by the temperature difference between the internal and external air. A comparison of the obtained results with the values of linear heat transfer coefficients known from the Standard for several typical wall units showed a discrepancy within 2.5%. Such accuracy level can be considered as satisfactory for the thermal calculations of enclosure structures. Given the ease of implementation, the developed method is recommended for use during calculations of the energy performance of buildings.
  • Item
    Особливості використання піноскла в якості теплоізоляції в цивільних будівлях
    (ЦНТУ, 2018) Процик, К. М.; Омелянчук, І. М.; Джирма, С. О.; Protsyk, K.; Omelianchuk, I.; Dzhyrma, S.
  • Item
    Вибір показників теплової надійності огороджувальних конструкцій
    (Луцький НТУ, 2017) Пашинський, В. А.; Джирма, С. О.; Плотніков, О. А.; Pashynskyi, V.; Dzhyrma, S.; Plotnikov, O.
    На базі аналізу рівня теплової надійності огороджувальних конструкцій, запроектованих згідно з вимогами ДБН В.2.6-31:2016, розроблені отримано допустимі значення відносної тривалості теплових відмов за критеріями комфортності перебування поблизу стін та утворення конденсату на їх внутрішній поверхні. The article discloses suggestions for the selection of an appropriate level of thermal sufficiency of the walling of residential and public buildings. As an indicator of thermal sufficiency it is recommended to use the relative duration of the state of thermal failure. According to the method developed earlier the relative duration of the thermal failure condition of walling has been determined. The resistance to heat transfer in the conditions of different regions of Ukraine corresponds to the requirements of the current thermal insulation of buildings on the absence of condensation on the internal surfaces of walls and the comfort of staying at external walls. The obtained results vary significantly across the territory but their generalization to the safety margin allowed establishing the maximum permissible value of the relative duration of the thermal failure state equal to 0.005 for the walls of residential and public buildings of the sufficiency class CC 2 and 0.001 for the buildings of the sufficiency class CC 3.