Наукові публікації кафедри БДМБ
Permanent URI for this collectionhttps://dspace.kntu.kr.ua/handle/123456789/1353
Browse
35 results
Search Results
Item Providing the thermal reliability of window junctions during the thermal modernization of civil buildings(2020) Pashynskyi, M.; Dzhyrma, S.; Pashynskyi, V.; Nastoyashchiy, V.; Пашинський, М. В.; Джирма, С. О.; Пашинський, В. А.; Настоящий, В. А.In order to assess the possibility of condensation on an internal window jamb surface, the temperature fields of window junctions to brick and precast concrete walls of civil buildings were analyzed, which were massively produced in the second half of the twentieth century. This study obtained the dependences of the jamb temperature on the thickness of the additional insulation layer and the outdoor temperature. Additionally, it showed the possibility of adjusting the jamb temperature by shifting the window frame inside the building. Outside air temperatures at which no condensation will occur in the initial junction structures and after thermal modernization by additional facade insulation were determined. The results can be used to replace worn-out windows and during the thermal modernization of buildings.Item Досвід розрахунково-екпериментального оцінювання енергетичних показників будівлі школи(НУВГП, 2020) Настоящий, В. А.; Пашинський, В. А.; Пашинський, М. В.; Джирма, С. О.; Nastoiashchyi., V.; Pashynskyi, V.; Pashynskyi, M.; Dzhyrma, S.Висвітлена методика і результати оцінювання показників енергетичної ефективності будівлі школи з урахуванням теплових характеристик огороджувальних конструкцій, отриманих за даними вимірювань у процесі натурних обстежень. Проаналізовано вплив термомодернізації на клас енергетичної ефективності будівлі. During the examination, numerous damages of the outer wall cladding, unfilled seams between the wall blocks and poorly executed junction of window and door frames to a wall were revealed, where heat transfer is highly increased due to air leakage from the inside of the building. The actual values of the heat transfer resistance of walls and translucent structures, experimentally established using a thermohygrometer, do not meet the requirements of current standards. Examination of the outer walls and window blocks using a thermal imager revealed thermal anomalies that significantly reduce the thermal insulation characteristics of enclosure structures. It is noted that the use of technical devices makes it easy to detect thermal anomalies and to estimate the characteristics of enclosure structures. Based on the research results, an energy passport of the building was developed. The design value of specific energy consumption is 55.7 kW×h/m3. Taking into account the maximum value of 35 kW×h/m3 for educational institutions, that are a subject of thermal modernization, the building was examined and classified as energy efficiency class F. Design proposals have been developed for thermal modernization of the building by using ventilated facade systems with rockwool insulation. After thermal modernization, the specific energy consumption are reduced to 34.7 kW×h/m2, and the energy efficiency is improving to class C.Item Методика аналізу процесу теплопередачі у вузлах огороджувальних конструкцій будівель(ОДАБА, 2020) Джирма, С. О.; Пашинський, В. А.; Настоящий, В. А.; Пашинський, М. В.Розроблена методика визначення втрат тепла через вузли огороджувальних конструкцій довільної форми. Методика базується на аналізі температури внутрішньої поверхні огороджень і дозволяє визначати втрати тепла в зонах лінійних теплопровідних включень та відповідні лінійні коефіцієнти теплопередачі. Встановлені параметри чисельного розв'язку, які гарантують достатню точність результатів. Виконані приклади визначення втрат тепла та лінійних коефіцієнтів теплопередачі для характерних вузлів стін житлових і громадських будівель. Достовірність результатів підтверджена шляхом порівняння лінійних коефіцієнтів теплопередачі з відомими даними для типових вузлів. The energy needs of buildings should be determined taking into account heat losses through zones of increased thermal conductivity in the junctions of enclosure structures. For this, linear heat transfer coefficients are used, which are given in the Ukrainian standard for a number of typical junctions. Non-standard solutions of junctions of enclosure structures require the development of a simple method for determining heat loss, which can be used for the design of real buildings. The proposed method is based on the analysis of the process of heat transfer from internal air to the inner surface of the enclosure. To determine the amount of heat, it is necessary to select a junction with adjacent flat sections of the enclosure and by two-dimensional computer simulation to determine the temperature on the inner surface of the enclosure. The amount of heat transferred is determined by numerical integration of the temperature difference between the internal air and the inner surface of the enclosure, taking into account the heat transfer coefficient of this surface. By the multi-variant calculations, it was found that the width of the adjacent junctions to the flat wall sections should be about two thicknesses of the wall. For a sufficiently accurate determination of heat loss using the trapezoidal rule, the discretization step of the temperature of the inner surface should not exceed 40 ... 50 mm. The developed technique also allows to determine the linear heat transfer coefficient of the junction. It is equal to the difference between the total amount of heat transferred and the amount of heat that can be transmitted through the flat sections of the enclosure, divided by the temperature difference between the internal and external air. A comparison of the obtained results with the values of linear heat transfer coefficients known from the Standard for several typical wall units showed a discrepancy within 2.5%. Such accuracy level can be considered as satisfactory for the thermal calculations of enclosure structures. Given the ease of implementation, the developed method is recommended for use during calculations of the energy performance of buildings.Item Дослідження теплових характеристик вузлів примикання віконних блоків з ПВХ в монолітних стінах(ЦНТУ, 2018) Ружич, Р. А.; Джирма, С. О.; Ruzhych, R.; Dzhyrma, S.Item Типи і галузі використання сучасних світлопрозорих огороджуючих конструкцій, та їх місце у забезпеченні енергоефективності будівель(ЦНТУ, 2018) Гамаюнова, С. А.; Джирма, С. О.; Hamaiunova, S.; Dzhyrma, S.Item Дослідження впливу положення вікон з ПВХ в товщі стін на тепловтрати існуючих житлових будівель вторинного ринку нерухомості в м. Кіровоград(КНТУ, 2016) Тукало, О. С.; Джирма, С. О.; Tukalo, O.; Dzhyrma, S.Item Конструктивні особливості зведення малоповерхових будинків на основі застосування легких сталевих тонкостінних конструкцій (ЛСТК)(ЦНТУ, 2018) Соколов, О. М.; Джирма, С. О.; Sokolov, O.; Dzhyrma, S.Item Ефективність використання 3D панелей у сучасному будівництві(ЦНТУ, 2018) Рябуха, І. К.; Джирма, С. О.; Плотніков, О. А.; Riabukha, I.; Dzhyrma, S.; Plotnikov, O.Item Особливості використання піноскла в якості теплоізоляції в цивільних будівлях(ЦНТУ, 2018) Процик, К. М.; Омелянчук, І. М.; Джирма, С. О.; Protsyk, K.; Omelianchuk, I.; Dzhyrma, S.Item Перспективи переходу від стальних арматурних виробів до пластикових(ЦНТУ, 2018) Кирилюк, І. М.; Джирма, С. О.; Плотніков, О. А.; Kyryliuk, I.; Dzhyrma, S.; Plotnikov, O.